RESEARCH ON LOW AND HIGH CYCLE FATIGUE BEHAVIOR OF NI-CR ALLOY UNDER DIFFERENT FREQUENCY AT ROOM TEMPERATURE

Low cycle fatigue test(0.1 Hz <sup> </sup>0.3 Hz,10~3<sup> </sup>10~5 cycles) and conventional high cycle fatigue test(150 Hz.10~4<sup> </sup>10~7 cycles) and ultra-high cycle fatigue test(20 k Hz,10~5<sup> </sup>10~9 cycles) were carried on Ni-Cr Allo...

Full description

Saved in:
Bibliographic Details
Main Authors: WU HaiLi, AN ChunXiang, YU Xiao, LU LianTao
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Strength 2018-01-01
Series:Jixie qiangdu
Subjects:
Online Access:http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2018.04.012
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Low cycle fatigue test(0.1 Hz <sup> </sup>0.3 Hz,10~3<sup> </sup>10~5 cycles) and conventional high cycle fatigue test(150 Hz.10~4<sup> </sup>10~7 cycles) and ultra-high cycle fatigue test(20 k Hz,10~5<sup> </sup>10~9 cycles) were carried on Ni-Cr Alloy at room temperature.The results of the three forms fatigue test were compared,and the energy-life curve reduced by 3-parameters power function were fitted.The fractograph of specimens were investigated and analyzed with scanning electron microscope.The results show that the fatigue crack initiation sites change from multiple surface cracks to single surface crack,then to subsurface of specimen with decreasing the load amplitude.
ISSN:1001-9669