USE OF THE ABSORPTION LITHIUM BROMIDE REFRIGERATING MACHINE FOR INCREASE IN OVERALL PERFORMANCE OF COMPRESSED-AIR POWER STATION

The scheme of compressed-air power plant with use, during recession of electric loading, the absorption lithium bromide refrigerating machinefor additional cooling of compressed air in an aftercooler in front of the air accumulator is offered. The technical and economic analysis of possible variants...

Full description

Saved in:
Bibliographic Details
Main Authors: R. Z. Aminov, S. V. Novichkov
Format: Article
Language:English
Published: Kazan State Power Engineering University 2018-04-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/468
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846155462433570816
author R. Z. Aminov
S. V. Novichkov
author_facet R. Z. Aminov
S. V. Novichkov
author_sort R. Z. Aminov
collection DOAJ
description The scheme of compressed-air power plant with use, during recession of electric loading, the absorption lithium bromide refrigerating machinefor additional cooling of compressed air in an aftercooler in front of the air accumulator is offered. The technical and economic analysis of possible variants of change in structure and duration of operation of the compressor and turbine equipment of compressed-air power plant in connection with additional decrease in temperature of compressed air when using absorption lithium bromide refrigerating machineby 10 – 20 ºС is carried out. The variant of introduction of absorption lithium bromide refrigerating machine in the scheme of compressed-air power plant at which profiles of the compressor and gas turbine don't change and changes the duration of their work, it appears more effective.
format Article
id doaj-art-0aa614550a2a45cd8ace2f7f8eb1f8d5
institution Kabale University
issn 1998-9903
language English
publishDate 2018-04-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj-art-0aa614550a2a45cd8ace2f7f8eb1f8d52024-11-26T11:39:37ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032018-04-011911-12627210.30724/1998-9903-2017-19-11-12-62-72460USE OF THE ABSORPTION LITHIUM BROMIDE REFRIGERATING MACHINE FOR INCREASE IN OVERALL PERFORMANCE OF COMPRESSED-AIR POWER STATIONR. Z. Aminov0S. V. Novichkov1Saratov Scientific Center of the Russian Academy of Sciences; Yuri Gagarin State Technical University of SaratovYuri Gagarin State Technical University of SaratovThe scheme of compressed-air power plant with use, during recession of electric loading, the absorption lithium bromide refrigerating machinefor additional cooling of compressed air in an aftercooler in front of the air accumulator is offered. The technical and economic analysis of possible variants of change in structure and duration of operation of the compressor and turbine equipment of compressed-air power plant in connection with additional decrease in temperature of compressed air when using absorption lithium bromide refrigerating machineby 10 – 20 ºС is carried out. The variant of introduction of absorption lithium bromide refrigerating machine in the scheme of compressed-air power plant at which profiles of the compressor and gas turbine don't change and changes the duration of their work, it appears more effective.https://www.energyret.ru/jour/article/view/468compressed-air power stationabsorption lithium bromide refrigerating machinecompressed air energy storageelectrical capacitynet present value
spellingShingle R. Z. Aminov
S. V. Novichkov
USE OF THE ABSORPTION LITHIUM BROMIDE REFRIGERATING MACHINE FOR INCREASE IN OVERALL PERFORMANCE OF COMPRESSED-AIR POWER STATION
Известия высших учебных заведений: Проблемы энергетики
compressed-air power station
absorption lithium bromide refrigerating machine
compressed air energy storage
electrical capacity
net present value
title USE OF THE ABSORPTION LITHIUM BROMIDE REFRIGERATING MACHINE FOR INCREASE IN OVERALL PERFORMANCE OF COMPRESSED-AIR POWER STATION
title_full USE OF THE ABSORPTION LITHIUM BROMIDE REFRIGERATING MACHINE FOR INCREASE IN OVERALL PERFORMANCE OF COMPRESSED-AIR POWER STATION
title_fullStr USE OF THE ABSORPTION LITHIUM BROMIDE REFRIGERATING MACHINE FOR INCREASE IN OVERALL PERFORMANCE OF COMPRESSED-AIR POWER STATION
title_full_unstemmed USE OF THE ABSORPTION LITHIUM BROMIDE REFRIGERATING MACHINE FOR INCREASE IN OVERALL PERFORMANCE OF COMPRESSED-AIR POWER STATION
title_short USE OF THE ABSORPTION LITHIUM BROMIDE REFRIGERATING MACHINE FOR INCREASE IN OVERALL PERFORMANCE OF COMPRESSED-AIR POWER STATION
title_sort use of the absorption lithium bromide refrigerating machine for increase in overall performance of compressed air power station
topic compressed-air power station
absorption lithium bromide refrigerating machine
compressed air energy storage
electrical capacity
net present value
url https://www.energyret.ru/jour/article/view/468
work_keys_str_mv AT rzaminov useoftheabsorptionlithiumbromiderefrigeratingmachineforincreaseinoverallperformanceofcompressedairpowerstation
AT svnovichkov useoftheabsorptionlithiumbromiderefrigeratingmachineforincreaseinoverallperformanceofcompressedairpowerstation