FATIGUE PERFORMANCE ANALYSIS OF VASCULAR STENT BASED ON TWO-WAY FLUID-SOLID COUPLING (MT)
In order to evaluate the influence of the thickness of the stent on the fatigue strength after implantation of the blood vessel, we established a two-way fluid-solid coupling model of the blood vessel、stent and the blood in this paper. The ANSYS finite analysis software was used in this paper to sim...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Office of Journal of Mechanical Strength
2022-01-01
|
Series: | Jixie qiangdu |
Subjects: | |
Online Access: | http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2022.06.026 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841534379901321216 |
---|---|
author | YANG Hang MUHETAER KeLiMu WU Chuan YANG HaiKun |
author_facet | YANG Hang MUHETAER KeLiMu WU Chuan YANG HaiKun |
author_sort | YANG Hang |
collection | DOAJ |
description | In order to evaluate the influence of the thickness of the stent on the fatigue strength after implantation of the blood vessel, we established a two-way fluid-solid coupling model of the blood vessel、stent and the blood in this paper. The ANSYS finite analysis software was used in this paper to simulative analysis the fatigue performance of stent after implantation, the coupling calculation of structural solid mechanics analysis and fluid dynamics analysis is realized, and the numerical results of the stent under a blood pulsating load are obtained. According to the simulation results, the fatigue performance of the implanted stent is evaluated by Goodman criterion and dynamic safety factor. The results show that the multi-component nature of blood has a greater impact on the stress fluctuation of the stent; the thickness of the stent has almost no effect on the stress distribution of the stent, but has a greater impact on the fatigue performance. |
format | Article |
id | doaj-art-0a6ea1371d484e93b8f737a2e79cd879 |
institution | Kabale University |
issn | 1001-9669 |
language | zho |
publishDate | 2022-01-01 |
publisher | Editorial Office of Journal of Mechanical Strength |
record_format | Article |
series | Jixie qiangdu |
spelling | doaj-art-0a6ea1371d484e93b8f737a2e79cd8792025-01-15T02:39:45ZzhoEditorial Office of Journal of Mechanical StrengthJixie qiangdu1001-96692022-01-011461146836350337FATIGUE PERFORMANCE ANALYSIS OF VASCULAR STENT BASED ON TWO-WAY FLUID-SOLID COUPLING (MT)YANG HangMUHETAER KeLiMuWU ChuanYANG HaiKunIn order to evaluate the influence of the thickness of the stent on the fatigue strength after implantation of the blood vessel, we established a two-way fluid-solid coupling model of the blood vessel、stent and the blood in this paper. The ANSYS finite analysis software was used in this paper to simulative analysis the fatigue performance of stent after implantation, the coupling calculation of structural solid mechanics analysis and fluid dynamics analysis is realized, and the numerical results of the stent under a blood pulsating load are obtained. According to the simulation results, the fatigue performance of the implanted stent is evaluated by Goodman criterion and dynamic safety factor. The results show that the multi-component nature of blood has a greater impact on the stress fluctuation of the stent; the thickness of the stent has almost no effect on the stress distribution of the stent, but has a greater impact on the fatigue performance.http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2022.06.026Finite elementFluid-solid couplingFatigueGoodman criterionDynamic safety factor |
spellingShingle | YANG Hang MUHETAER KeLiMu WU Chuan YANG HaiKun FATIGUE PERFORMANCE ANALYSIS OF VASCULAR STENT BASED ON TWO-WAY FLUID-SOLID COUPLING (MT) Jixie qiangdu Finite element Fluid-solid coupling Fatigue Goodman criterion Dynamic safety factor |
title | FATIGUE PERFORMANCE ANALYSIS OF VASCULAR STENT BASED ON TWO-WAY FLUID-SOLID COUPLING (MT) |
title_full | FATIGUE PERFORMANCE ANALYSIS OF VASCULAR STENT BASED ON TWO-WAY FLUID-SOLID COUPLING (MT) |
title_fullStr | FATIGUE PERFORMANCE ANALYSIS OF VASCULAR STENT BASED ON TWO-WAY FLUID-SOLID COUPLING (MT) |
title_full_unstemmed | FATIGUE PERFORMANCE ANALYSIS OF VASCULAR STENT BASED ON TWO-WAY FLUID-SOLID COUPLING (MT) |
title_short | FATIGUE PERFORMANCE ANALYSIS OF VASCULAR STENT BASED ON TWO-WAY FLUID-SOLID COUPLING (MT) |
title_sort | fatigue performance analysis of vascular stent based on two way fluid solid coupling mt |
topic | Finite element Fluid-solid coupling Fatigue Goodman criterion Dynamic safety factor |
url | http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2022.06.026 |
work_keys_str_mv | AT yanghang fatigueperformanceanalysisofvascularstentbasedontwowayfluidsolidcouplingmt AT muhetaerkelimu fatigueperformanceanalysisofvascularstentbasedontwowayfluidsolidcouplingmt AT wuchuan fatigueperformanceanalysisofvascularstentbasedontwowayfluidsolidcouplingmt AT yanghaikun fatigueperformanceanalysisofvascularstentbasedontwowayfluidsolidcouplingmt |