STUDY ON CONSTRAINT OF MIXED MODE CRACK AND FAILURE ASSESSMENT DIAGRAM OF PRESSURE-BEARING STRUCTURE

The crack tip constraint and failure assessment diagram (FAD) in both plate specimen and pipe structure were the focus of analysis, with the goal of studying compatibility and correlation of between the two.Based on the finite element method,constraints at crack tip of central cracked plate (CCP) sp...

Full description

Saved in:
Bibliographic Details
Main Authors: MIAO XinTing, ZHANG JinBo, LIU GuoXu, PENG Jian, BIE FengFeng
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Strength 2024-01-01
Series:Jixie qiangdu
Subjects:
Online Access:http://www.jxqd.net.cn/thesisDetails?columnId=67195791&Fpath=home&index=0
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841534053417746432
author MIAO XinTing
ZHANG JinBo
LIU GuoXu
PENG Jian
BIE FengFeng
author_facet MIAO XinTing
ZHANG JinBo
LIU GuoXu
PENG Jian
BIE FengFeng
author_sort MIAO XinTing
collection DOAJ
description The crack tip constraint and failure assessment diagram (FAD) in both plate specimen and pipe structure were the focus of analysis, with the goal of studying compatibility and correlation of between the two.Based on the finite element method,constraints at crack tip of central cracked plate (CCP) specimen and cracked pressure pipe were obtained.It was found that crack tip constraint of CCP specimen under uniaxial loading is better matched with thick-walled pipeline under axial tensile loading,while CCP specimen under biaxial loading is better matched with thin-walled pipeline under internal pressure.In addition,the failure assessment diagram of CCP specimen and pipeline were obtained.It was found that FAD of CCP specimen is less related with thickness,when the thickness of pipe is within the range of thick wall or thin wall; was also pointed out that stress parallel to the crack direction increases the failure assessment curve (FAC) of the structure.Finally,it is found that FAC of the central crack plate specimen is higher than that of the pressure bearing pipeline,for the two structures with the same constraint level,and crack tip mixed mode degree and loading mode.That is,it is unsafe to use FAD of CCP specimen to evaluate pipeline.
format Article
id doaj-art-06d39bfceb5440fda07b3776f9a41ce7
institution Kabale University
issn 1001-9669
language zho
publishDate 2024-01-01
publisher Editorial Office of Journal of Mechanical Strength
record_format Article
series Jixie qiangdu
spelling doaj-art-06d39bfceb5440fda07b3776f9a41ce72025-01-15T02:45:46ZzhoEditorial Office of Journal of Mechanical StrengthJixie qiangdu1001-96692024-01-0111067195791STUDY ON CONSTRAINT OF MIXED MODE CRACK AND FAILURE ASSESSMENT DIAGRAM OF PRESSURE-BEARING STRUCTUREMIAO XinTingZHANG JinBoLIU GuoXuPENG JianBIE FengFengThe crack tip constraint and failure assessment diagram (FAD) in both plate specimen and pipe structure were the focus of analysis, with the goal of studying compatibility and correlation of between the two.Based on the finite element method,constraints at crack tip of central cracked plate (CCP) specimen and cracked pressure pipe were obtained.It was found that crack tip constraint of CCP specimen under uniaxial loading is better matched with thick-walled pipeline under axial tensile loading,while CCP specimen under biaxial loading is better matched with thin-walled pipeline under internal pressure.In addition,the failure assessment diagram of CCP specimen and pipeline were obtained.It was found that FAD of CCP specimen is less related with thickness,when the thickness of pipe is within the range of thick wall or thin wall; was also pointed out that stress parallel to the crack direction increases the failure assessment curve (FAC) of the structure.Finally,it is found that FAC of the central crack plate specimen is higher than that of the pressure bearing pipeline,for the two structures with the same constraint level,and crack tip mixed mode degree and loading mode.That is,it is unsafe to use FAD of CCP specimen to evaluate pipeline.http://www.jxqd.net.cn/thesisDetails?columnId=67195791&Fpath=home&index=0Mixed mode crackConstraintFADPressure structure
spellingShingle MIAO XinTing
ZHANG JinBo
LIU GuoXu
PENG Jian
BIE FengFeng
STUDY ON CONSTRAINT OF MIXED MODE CRACK AND FAILURE ASSESSMENT DIAGRAM OF PRESSURE-BEARING STRUCTURE
Jixie qiangdu
Mixed mode crack
Constraint
FAD
Pressure structure
title STUDY ON CONSTRAINT OF MIXED MODE CRACK AND FAILURE ASSESSMENT DIAGRAM OF PRESSURE-BEARING STRUCTURE
title_full STUDY ON CONSTRAINT OF MIXED MODE CRACK AND FAILURE ASSESSMENT DIAGRAM OF PRESSURE-BEARING STRUCTURE
title_fullStr STUDY ON CONSTRAINT OF MIXED MODE CRACK AND FAILURE ASSESSMENT DIAGRAM OF PRESSURE-BEARING STRUCTURE
title_full_unstemmed STUDY ON CONSTRAINT OF MIXED MODE CRACK AND FAILURE ASSESSMENT DIAGRAM OF PRESSURE-BEARING STRUCTURE
title_short STUDY ON CONSTRAINT OF MIXED MODE CRACK AND FAILURE ASSESSMENT DIAGRAM OF PRESSURE-BEARING STRUCTURE
title_sort study on constraint of mixed mode crack and failure assessment diagram of pressure bearing structure
topic Mixed mode crack
Constraint
FAD
Pressure structure
url http://www.jxqd.net.cn/thesisDetails?columnId=67195791&Fpath=home&index=0
work_keys_str_mv AT miaoxinting studyonconstraintofmixedmodecrackandfailureassessmentdiagramofpressurebearingstructure
AT zhangjinbo studyonconstraintofmixedmodecrackandfailureassessmentdiagramofpressurebearingstructure
AT liuguoxu studyonconstraintofmixedmodecrackandfailureassessmentdiagramofpressurebearingstructure
AT pengjian studyonconstraintofmixedmodecrackandfailureassessmentdiagramofpressurebearingstructure
AT biefengfeng studyonconstraintofmixedmodecrackandfailureassessmentdiagramofpressurebearingstructure