Evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sources
Studies and evaluations of the detector characteristics of a high-resolution multichamber alpha spectrometer and its calibration using certified mixed standard sources of 239Pu, 241Am, and 244Cm for measuring alpha-emitting radionuclides dedicated to environmental samples. The efficiency and resolut...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2024-11-01
|
Series: | Radiation Protection and Environment |
Subjects: | |
Online Access: | https://journals.lww.com/10.4103/rpe.rpe_29_24 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841537089496154112 |
---|---|
author | Satyanarayan Bramha S. Chandrasekaran |
author_facet | Satyanarayan Bramha S. Chandrasekaran |
author_sort | Satyanarayan Bramha |
collection | DOAJ |
description | Studies and evaluations of the detector characteristics of a high-resolution multichamber alpha spectrometer and its calibration using certified mixed standard sources of 239Pu, 241Am, and 244Cm for measuring alpha-emitting radionuclides dedicated to environmental samples. The efficiency and resolution were evaluated for each potential distance between the source and the detector across all four solid-state ORTEC-ULTRA AS detectors. The results obtained from the characteristics performance of the alpha from the standard alpha sources are described in detail in the paper, and also a case study for the environmental application shows very good recovery using the alpha spectrometer. |
format | Article |
id | doaj-art-02da114833c54af89a141b80ba78ece9 |
institution | Kabale University |
issn | 0972-0464 2250-0995 |
language | English |
publishDate | 2024-11-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Radiation Protection and Environment |
spelling | doaj-art-02da114833c54af89a141b80ba78ece92025-01-14T08:56:44ZengWolters Kluwer Medknow PublicationsRadiation Protection and Environment0972-04642250-09952024-11-0147320521010.4103/rpe.rpe_29_24Evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sourcesSatyanarayan BramhaS. ChandrasekaranStudies and evaluations of the detector characteristics of a high-resolution multichamber alpha spectrometer and its calibration using certified mixed standard sources of 239Pu, 241Am, and 244Cm for measuring alpha-emitting radionuclides dedicated to environmental samples. The efficiency and resolution were evaluated for each potential distance between the source and the detector across all four solid-state ORTEC-ULTRA AS detectors. The results obtained from the characteristics performance of the alpha from the standard alpha sources are described in detail in the paper, and also a case study for the environmental application shows very good recovery using the alpha spectrometer.https://journals.lww.com/10.4103/rpe.rpe_29_24alpha spectrometryenergy and efficiency calibrationfull width at half maximumself-absorption |
spellingShingle | Satyanarayan Bramha S. Chandrasekaran Evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sources Radiation Protection and Environment alpha spectrometry energy and efficiency calibration full width at half maximum self-absorption |
title | Evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sources |
title_full | Evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sources |
title_fullStr | Evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sources |
title_full_unstemmed | Evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sources |
title_short | Evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sources |
title_sort | evaluation and assessments of efficiency calibration and resolution of an alpha spectrometry system using standard sources |
topic | alpha spectrometry energy and efficiency calibration full width at half maximum self-absorption |
url | https://journals.lww.com/10.4103/rpe.rpe_29_24 |
work_keys_str_mv | AT satyanarayanbramha evaluationandassessmentsofefficiencycalibrationandresolutionofanalphaspectrometrysystemusingstandardsources AT schandrasekaran evaluationandassessmentsofefficiencycalibrationandresolutionofanalphaspectrometrysystemusingstandardsources |