Investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction (Case study: Semnan wind-Catchers)

The purpose of this study is to investigate the role and importance of traditional Iranian architecture with emphasis on wind-catcher in reducing energy consumption in residential homes. Semnan province was selected as a study area and in the first step, suitable areas were identified for the establ...

Full description

Saved in:
Bibliographic Details
Main Authors: Mahdi Yahyaei, Seyed Majid Mofidi Shemirani, Vahid Ahmadi
Format: Article
Language:English
Published: OICC Press 2021-09-01
Series:Anthropogenic Pollution
Subjects:
Online Access:http://oiccpress.com/ap/article/view/3465
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846159301097291776
author Mahdi Yahyaei
Seyed Majid Mofidi Shemirani
Vahid Ahmadi
author_facet Mahdi Yahyaei
Seyed Majid Mofidi Shemirani
Vahid Ahmadi
author_sort Mahdi Yahyaei
collection DOAJ
description The purpose of this study is to investigate the role and importance of traditional Iranian architecture with emphasis on wind-catcher in reducing energy consumption in residential homes. Semnan province was selected as a study area and in the first step, suitable areas were identified for the establishment of wind-catcher in the province. In the second step, using two indices of Olgyay and effective temperature index (ET), the ted-cmperature of thermal comfort in the province was determined. Finally, the temperature difference was calculated by comparing the temperature in the residential houses adjacent to the wind-catcher and the internal temperature of the traditional buildings that had win-catchers. In the final step, the amount of energy consumption for heating or cooling in residential houses in Semnan province was estimated to determine the role and importance of wind-catchers. The results showed that April, May, June and October are in the zone of thermal comfort and there are times when wind-catchers will not be very useful in the province. On the other hand, July, August and September due to high temperatures and December, January, February and March due to high cold are good times to use wind-catchers. Also, the highest degree of conformity of the measured temperatures is observed in the cities of Semnan, Garmsar, Damghan and Shahrood, respectively. The amount of energy required to produce cooling is equal to 1700 kWh. However, if a wind-catcher is used, due to the reduction of coefficients and refrigeration losses, this amount will be equal to 1200 kWh.
format Article
id doaj-art-011ff8ff8d424d2388160b6b479ed6f9
institution Kabale University
issn 2783-1736
2588-4646
language English
publishDate 2021-09-01
publisher OICC Press
record_format Article
series Anthropogenic Pollution
spelling doaj-art-011ff8ff8d424d2388160b6b479ed6f92024-11-23T11:15:16ZengOICC PressAnthropogenic Pollution2783-17362588-46462021-09-015210.22034/ap.2021.1936671.1116Investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction (Case study: Semnan wind-Catchers)Mahdi Yahyaei0Seyed Majid Mofidi Shemirani1Vahid Ahmadi2Department of Architecture, Mashhad Branch, Islamic Azad University, Mashhad, IranDepartment of Architecture, Faculty of Architecture and Urbanism, Iran University of Science & Technology, Tehran, IranDepartment of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, IranThe purpose of this study is to investigate the role and importance of traditional Iranian architecture with emphasis on wind-catcher in reducing energy consumption in residential homes. Semnan province was selected as a study area and in the first step, suitable areas were identified for the establishment of wind-catcher in the province. In the second step, using two indices of Olgyay and effective temperature index (ET), the ted-cmperature of thermal comfort in the province was determined. Finally, the temperature difference was calculated by comparing the temperature in the residential houses adjacent to the wind-catcher and the internal temperature of the traditional buildings that had win-catchers. In the final step, the amount of energy consumption for heating or cooling in residential houses in Semnan province was estimated to determine the role and importance of wind-catchers. The results showed that April, May, June and October are in the zone of thermal comfort and there are times when wind-catchers will not be very useful in the province. On the other hand, July, August and September due to high temperatures and December, January, February and March due to high cold are good times to use wind-catchers. Also, the highest degree of conformity of the measured temperatures is observed in the cities of Semnan, Garmsar, Damghan and Shahrood, respectively. The amount of energy required to produce cooling is equal to 1700 kWh. However, if a wind-catcher is used, due to the reduction of coefficients and refrigeration losses, this amount will be equal to 1200 kWh.http://oiccpress.com/ap/article/view/3465Energy consumptionOlgyay indexSemnanThermal ComfortWind-catcher
spellingShingle Mahdi Yahyaei
Seyed Majid Mofidi Shemirani
Vahid Ahmadi
Investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction (Case study: Semnan wind-Catchers)
Anthropogenic Pollution
Energy consumption
Olgyay index
Semnan
Thermal Comfort
Wind-catcher
title Investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction (Case study: Semnan wind-Catchers)
title_full Investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction (Case study: Semnan wind-Catchers)
title_fullStr Investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction (Case study: Semnan wind-Catchers)
title_full_unstemmed Investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction (Case study: Semnan wind-Catchers)
title_short Investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction (Case study: Semnan wind-Catchers)
title_sort investigating the role and importance of sustainable architecture in optimal fuel consumption and pollution reduction case study semnan wind catchers
topic Energy consumption
Olgyay index
Semnan
Thermal Comfort
Wind-catcher
url http://oiccpress.com/ap/article/view/3465
work_keys_str_mv AT mahdiyahyaei investigatingtheroleandimportanceofsustainablearchitectureinoptimalfuelconsumptionandpollutionreductioncasestudysemnanwindcatchers
AT seyedmajidmofidishemirani investigatingtheroleandimportanceofsustainablearchitectureinoptimalfuelconsumptionandpollutionreductioncasestudysemnanwindcatchers
AT vahidahmadi investigatingtheroleandimportanceofsustainablearchitectureinoptimalfuelconsumptionandpollutionreductioncasestudysemnanwindcatchers